| Electrical data |
| Power supply type : |
Alternating current |
| Working voltage [V]: |
20 ÷ 250 |
| Protection class : |
III |
| Outputs |
| Function : |
NO |
| Max voltage drop [V]: |
< 6 |
| Max output current [mA]: |
300 |
| Minimum output current [mA]: |
5 |
| Max peak current [A]: |
1.5 |
| Residual current [mA]: |
< 1 |
| Max switching frequency [Hz]: |
12 |
| Detection zone |
| Switching distance-Sn [mm]: |
4 |
| Real sensing distance-Sr [mm]: |
4 ±10% |
| Operative distance-So [mm]: |
0 ÷ 3.24 |
| Accuracy and Deviations |
| Correction factor : |
Stainless steel: 0.9 - Brass: 0.5 - Aluminium: 0.4 - Copper: 0.4 |
| Hysteresis [%Sr]: |
< 10 |
| Switching point drift [%Sr]: |
-1 |
| Repeatability [%Sn]: |
< 3 |
| Environmental conditions |
| Temperature limits [°C]: |
-25°C ÷ +70°C |
| IP rating : |
IP65-IP66-IP67 |
| Display and control elements |
| Display : |
Output switching status - 1 x LED: Yellow |
| Mechanical data |
| Housing : |
Threded type |
| Thread designation : |
M12x1 |
| Dimensions [mm]: |
M12x1 - L=67.5 |
| Materials : |
Housing: Nickel-plated brass - Sensing area: POM blue - Lock nuts: Nickel-plated brass |
| Mounting : |
Not embeddable |
| Weigth [g]: |
80 |
| Electrical connection |
| Cable : |
2 m - PVC/PVC - 2 x 0.25 mm² |
| Compliance to Standards / Directives |
| Directives compliance : |
2014/30/EU -Electromagnetic compatibility directive (EMC) 2014/35/UE -Low voltage directive (LVD) |
| Standards compliance : |
EN60947-5-2 - Product standard |