| Electrical data |
| Power supply type: |
Direct current |
| Operating voltage [V]: |
5 ÷ 30 |
| Current draw [mA]: |
On <= 1 mA - Off >= 3 mA @ 8.2V |
| Insulation class: |
III |
| Reverse polarity protection: |
Up to 8.5V |
| Exits |
| Electric model: |
Namur |
| Residual current [mA]: |
< 1 mA |
| Maximum working frequency [Hz]: |
2000 |
| Detection field |
| Nominal operating distance-Sn [mm]: |
2 |
| Actual operating distance-Sr [mm]: |
2 ±10% |
| Operating distance-So [mm]: |
0 ÷ 1.62 |
| Accuracy and Drift |
| Correction factor: |
Stainless steel: 0.9 - Brass: 0.5 - Aluminum: 0.4 - Copper: 0.4 |
| Switching point drift [%Sr]: |
-1 |
| Repeatability [%Sn]: |
< 3 |
| Environmental conditions |
| Temperature limits [°C]: |
-25°C ÷ +70°C |
| Degree of protection: |
IP65-IP66-IP67 |
| Mechanical data |
| Body: |
Threaded type |
| Thread definition: |
M12x1 |
| Dimensions [mm]: |
M12x1 - L=41 |
| Materials: |
Body: Nickel-plated brass - sensitive area: red POM - Fixing rings: Nickel-plated brass |
| Assembly: |
Screened |
| Weight [g]: |
70 |
| Electrical connection |
| Cable: |
3 m - PVC/PVC - 2 x 0.25 mm² |
| Compliance with Standards/Directives |
| Compliance with directives: |
2014/30/EU - Electromagnetic Compatibility (EMC) Directive |
| Compliance with standards: |
EN60947-5-6 - Product standard |